Most of us take advantage of the autozero function on our HPLC data systems to make the chromatogram look more pleasing to the eye. The autozero function is quite simple – it just takes whatever signal the data system is receiving and sets it at the...
Q: I’m wondering why most of scientists prefer to use a manual injector?! I know that autosamplers are used more to improve the productivity and it is standard with many HPLC systems. I was working with both and the autosampler produced better...
This discussion follows on the last HPLC Solutions instalment (HPLC Solutions #118), where we discussed the relative merits of manual injectors and autosamplers. A little better understanding of the loop filling characteristics will help us realize...
As a follow-up on the last two HPLC Solutions discussions (HPLC Solutions #118, #119) regarding sample injection, I’d like to take the opportunity to describe the two most popular types of autosamplers in use today. These are what I call the...
In the last instalment of (HPLC Solutions #120) we looked at one popular autosampler design, the push-to-fill autosampler. Now we’ll turn our attention to the other most popular design, which I call needle-in-loop.
This installment of HPLC Solutions begins a series on different measurements that we make on chromatograms. Measuring the baseline noise generated by an HPLC system may seem like a singularly boring subject. But if you think about it, noise can be a...
In HPLC Solutions #122, we looked at how to measure baseline noise from a liquid chromatogram. One practical application of such measurements is to determine the noise and drift of the detector, which we’ll consider now.
In HPLC Solutions #122, we looked at how to measure baseline noise from a liquid chromatogram. One practical application of such measurements is to determine the signal-to-noise ratio (S/N), which we’ll consider here.
As we saw in HPLC Solutions #125, the International Committee on Harmonization (ICH, 1) lists three ways to determine the limit of detection (LOD) or limit of quantification (LOQ):
With today’s data systems for HPLC, we tend to take peak measurement for granted. Much of the time we’re pretty safe if we use the default integration conditions, but this is not always the case. In this HPLC Solutions series on integration, we’ll...
In HPLC Solutions #127 we took a brief look at how HPLC integrators detect and measure a peak’s height or area. Much of the time the default settings for the data system are sufficient for reliable operation, but you may find that the integration...
In the first two parts of this series (HPLC Solutions #127 and #128), we looked at how HPLC data systems integrate chromatograms and some of the adjustments that can be made if you don’t like the way the default settings perform. Even with proper...
I’m sure you’ve all heard the proverb that says if you give a person a fish, you’ll feed them for a day, but if you teach a person to fish, you’ll enable them to feed themselves. There are lots of on-line options for “fishing lessons” through LC...
Posts by Topic
- Liquid Chromatography (LC) (173)
- Learning & Training (168)
- HPLC (63)
- Analytical Training Solutions (49)
- Videos & Tutorials (30)
- Methods & Applications (27)
- Method Development (22)
- Gel Permeation Chromatography (GPC) (21)
- Size Exclusion Chromatography (SEC) (18)
- LC-MS (17)
- UHPLC (17)
- HILIC (16)
- Webinars & eSeminars (15)
- Analytix Reporter (13)
- Events (11)
- Karl Fischer Titration (11)
- Sample Preparation (9)
- Columns (8)
- Supercritical Fluid Chromatography (SFC) (8)
- TLC / HPTLC (7)
- Food Quality (6)
- Protein Analysis (6)
- Lab Productivity (5)
- Pharma Drug Discovery (5)
- Bioclinical (4)
- Chromatography Software (4)
- Lab Operations (4)
- Food Flavours & Fragrances (3)
- Food Ingredients (3)
- Food Safety (3)
- GPC/SEC (3)
- ICP-OES (3)
- Ion Chromatography (IC / IC-MS) (3)
- LC-MS/MS (3)
- LIMS (3)
- Materials Testing (3)
- News (3)
- Preparative-scale Chromatography (3)
- Biopharma (2)
- Biopharma Protein & Peptide Analysis (2)
- Cosmetics (2)
- Data Integrity (2)
- Environmental Water (2)
- Ion Chromatography (2)
- LC-UV (2)
- Pharma Quality Assurance (2)
- Planar Chromatography (2)
- Proteomics (2)
- Reversed-Phase Chromatography (2)
- SEC-MALS (2)
- Sampling (2)
- Solid Phase Microextraction (SPME) (2)
- Spectroscopy ICP (2)
- AI (1)
- CDS (1)
- CRMs (1)
- Cannabis Testing (1)
- Charged Aerosol Detection (1)
- Convergence Chromatography (UPC) (1)
- Environmental Pesticide Analysis (1)
- GC-MS (1)
- Gas Chromatography (GC) (1)
- ICP-MS (1)
- LPLC (1)
- Ligand Xchange Chromatography (LEX) (1)
- PGC (1)
- Particle technologies (1)
- Petrochemical (1)
- Pharma Biologics & Biosimilars (1)
- Polymer Analysis (1)
- Proficiency Testing (1)
- Q-TOF (1)
- QuEChERS (1)
- Solid Phase Extraction (SPE) (1)
- Spectroscopy IR NIR (1)
- Spectroscopy UV VIS (1)
- Troubleshooting (1)
- chromatography data systems (1)
- consumables (1)
- eBook (1)
- intelligent software (1)
- tutorial (1)