View this on-demand presentation in which the speakers deliver the total solution for hydrogen impurities analysis including five different GC configurations.

Agilent_040523_OND_Blog_Header_600

 

Format: On-demand

Duration: Approximately 1 hour

Impurity analysis of different grades of hydrogen has become an urgent need for users. The impurities He, Ne, N2, Ar, and CH4 will dilute H2 concentration, and CO/CO2 will decrease the lifetime of the fuel cell. The presence of trace sulfides can lead to fuel cell catalysts poisoning.

In this presentation, the speakers deliver the total solution for hydrogen impurities analysis including five different GC configurations:

  • GC-TCD/FID for ppm-level total hydrocarbon analysis
  • GC-PDHID for CO2, CO, CH4, Ar, and N2 analysis at ppb level
  • GC-SCD for sulfur compounds
  • GCMS for the detection of formaldehyde
  • Micro GC for fast analysis of permanent gas

The results obtained from the flexible and diverse GC configurations show excellent performance of Agilent GC products. The solution can meet different analysis requirements of users. Speakers will also highlight the advantages of different configurations and how customers can choose the right GC products according to their own needs.

By viewing this presentation you will learn about:

  • Regulatory considerations for high-purity hydrogen impurities
  • Different GC platforms for hydrogen impurities analysis
  • Advantages of different GC configurations

The Presenters

youjuan_100Youjuan Zhang
Applications Chemist, Agilent Technologies, Gas Phase Separations Division
Youjuan joined Agilent in 2013 as an education engineer and focused on providing superior service and training to customers. She joined the GPSD marketing group as an applications chemist in 2017 and her responsibility included supporting NPI and developing applications with Agilent GC/GCMS products.

Scott_Hoy_100Scott Hoy 
Applications Chemist, Agilent Technologies, Gas Phase Separations Division 
Scott joined Agilent Technologies in 2021 following eight years of gas chromatography experience in petrochemical QC and R&D. As an applications chemist in GPSD, his focus is creating GC and GCxGC solutions to meet the evolving needs of customers and markets. Scott is an active member of ASTM D02. 

Sponsor:

Agilent_Logo_RGB

Published  Apr 27, 2023

Home 9 Techniques 9 Gas Chromatography 9 GC Solutions for Hydrogen Impurities Analysis