Accelerating Large-scale Proteomics with High-throughput Accurate Mass Spectrometry Workflows

by | Bioclinical, Data Acquisition & Analysis, Mass Spectrometry, Omics

Are you looking to find an accurate, reliable method for identifying and quantifying large numbers of proteins and peptides? If so, watch this on-demand webinar that discusses high-throughput mass spectrometry workflows for large-scale qualitative and quantitative proteomics.

Webinar_eDM_091122_Header_OND

Format: On-demand

Duration: 50 minutes

The limitations of data-dependent acquisition (DDA) strategies using mass spectrometry has driven the rapid adoption of data-independent acquisition (DIA or SWATH DIA) approaches, such as Zeno SWATH DIA. This method achieves 5-6x more MS/MS sensitivity, resulting in this DIA approach surpassing DDA for protein identifications and quantification in complex matrices. This advantage is further observed at short acquisition times that are required to meet the throughput demands of current proteomics studies.

This webinar comprises the two presentations below:-

Rapid and Robust Proteomes with Standardized Methods on the Evosep One Powered by Zeno SWATH DIA
by Dorte Bekker-Jensen, Senior Scientist, Evosep Biosystems

Robust, High-throughput Quantification of Peptides in Plasma using Zeno SWATH DIA
by Patrick Pribil, Senior Manager, SCIEX Proteomics Applications Development

By attending this presentation you will learn about:

  • innovations in accurate mass analysis delivering speed and accuracy for large-scale proteomics
  • the development of a standardized platform for robust, in-depth high-throughput proteome analysis
  • the impact of sensitivity gains on protein and peptide identification and quantification.

If you have a colleague who may also be interested in the subject of this webinar, please recommend it to them by using the link below.

The Presenters

Dorte_Bekker_Jensen_80CDorte Bekker-Jensen
Senior Scientist, Evosep Biosystems
Dorte works as a Senior Scientist at Evosep in the Application Development team. Evosep aims to make clinical proteomics 100 times more robust and 10 times faster by radically innovating sample preparation and separation prior to MS analysis.

Patrick_Pribil_80CPatrick Pribil
Senior Manager, SCIEX Proteomics Applications Development
Patrick Pribil completed his BSc in Biochemistry at McMaster University (Hamilton, Canada) in 1997, followed by his PhD in Biochemistry at The University of Western Ontario (London, Canada) in 2003. He spent 2 years as a Post-Doctoral Fellow at the University of Maryland, studying rapid identification of bacteria using MALDI-MS under Catherine Fenselau before joining SCIEX as an Applications Support Scientist in 2005. He has been an Applications Manager at SCIEX since 2013, managing teams supporting pharma, biopharma, proteomics, metabolomics and lipidomics applications before transitioning to the role of Senior Manager, Proteomics Applications Development in October 2022.

Sponsor:

SCIEX Logo 2019

Published  Oct 11, 2022

Home 9 Bioclinical 9 Accelerating Large-scale Proteomics with High-throughput Accurate Mass Spectrometry Workflows