Environmental Analysis

High-sensitivity method for the analysis of nonylphenol in river water using GC-MS/MS

In this application note, a method using a high selectivity triple quadrupole gas chromatography-mass spectrometer (GC–MS/MS) to detect for nonylphenol in river water is presented.

Highly sensitive MRM-based method for detection and quantitation of seven pharmaceuticals and PPCPs in surface water

Shimadzu has produced an application note describing a high sensitivity detection method for the detection of Pharmaceuticals and Personal Care Products (PPCPs) in surface water that does not require pre-treatment and concentration of water...

Highly sensitive LC/MS/MS method for direct quantitation of artificial sweeteners in surface water

Shimadzu has produced an application note describing an LC/MS/MS method for direct quantitation of artificial sweeteners in surface and drinking water.

Quantitative determination of phenols in surface water on LC/MS/MS with APCI interface

Shimadzu has produced an application note describing an MRM-based method for detection and quantitation of phenol and nine substituted phenols in reservoir water, without pre-treatment and pre-concentration.

Improved Analysis of Dioxin Compounds in Water by Isotope Dilution GC/MS/MS

Are you looking for an alternative, effective GC/MS/MS method for dioxin analysis in water? Would you like to reduce time-consuming sample preparation without highly sensitive and selective instrumentation? If so, Separation Science in...

Per- and Polyfluoroalkyl Substances in Drinking Water Using Solid-Phase Extraction and LC-MS/MS

UCT has produced an application note outlining a simple solid-phase extraction procedure for the extraction of 26 diverse per- and polyfluoroalkyl substances (PFASs) in drinking water using UCT’s polymeric weak-anion exchange SPE cartridges...

Lowering costs in your environmental lab...

Environmental laboratories are always looking for ways to save costs without compromising analytical results in terms of sensitivity, robustness or quality controls.

Increase Your Confidence in the Analysis of Environmental Samples with Tandem MS

In this presentation from an 'Advances in Environmental Analysis eSeminar' hosted by Separation Science in collaboration with Bruker, Ed George provides some tips on how to raise confidence in the analysis of environmental samples with tandem...

Fast, Accurate and Sensitive Detection of Trace Organics in Water – Learn more

Discover a fast and robust method for trace level detection of trace organic contaminants using the latest advances in triple quadrupole LC/MS technology.

Do you need a fast and robust method to achieve sensitive detection of organic contaminants...

New Chromatography Columns and Kit Offer Advanced Separations for Environmental and Industrial Markets

Thermo Scientific ion chromatography columns and gas chromatography kit support application flexibility.

Effective Method for Concentrating Semi-volatile Compounds from EPA Method 625

Biotage has produced an application note in which fifty semi-volatile compounds were concentrated using the new TurboVap® II evaporator according to the EPA Method 625. For each of them, six replicates were done to assess the analyte recovery and...

EPA Method 522: Determination of 1,4-Dioxane in Drinking Water by SPE and GC/MS with Selected Ion Monitoring

UCT has produced an application note describing an SPE approach coupled with GC/MS for the determination of the hazardous analyte, 1,4-dioxane in drinking water.

    